-40%

ZOLL M BIPHASIC MIAMI

$ 316.27

Availability: 100 in stock
  • Condition: Defibrillator Sold As Is. Tested. No paddles. With ECG Analyze. 3 Lead, Biphasic, Pacing, Batteries, Printer.
  • All returns accepted: ReturnsNotAccepted
  • Brand: ZOLL
  • MPN: Does Not Apply
  • Model: M
  • Product: Defibrillator Battery

    Description

    ZOLL M BIPHASIC DEFIBRILLATOR MIAMI
    3 Lead, Biphasic, Pacing, Batteries, Printer
    Features:
    * Unequaled portability. So easy to lift, position and carry, it will never be left behind. Built in AC makes the transition from transport to bedside easy.
    * Straightforward controls, intuitive menus, and ZOLL's Uniform Operating System make operation simple and reduce staff training requirement.
    * Our new high contrast screen with improved readability and wide angle view (60°) is superior to any LCD display.
    * Error correction minimizes problems during use by providing helpful prompts for corrective action.
    ECG Monitoring:
    * Patient Connection: 3-lead ECG cable, 5-lead ECG cable, 12-Lead ECG cable, paddles or MFE Pads. Selectable by front panel switch.
    * Input Protection: Fully defibrillator protected. Special circuit prevents distortion of ECG by pacer pulse. (Pacer version only.)
    * Implanted Pacemaker Spike Display: Dedicated circuitry detects most implanted pace-maker spikes and provides standard display marker of spike on ECG trace.
    * Bandwidth: 0.5-40 Hz (-3 dB) or 0.5-30Hz; 0.05-150 Hz diagnostic.
    * Lead Selection: Displayed on monitor.
    * ECG Size: 0.5, 1, 1.5, 2, 3 cm/mV - display on monitor.
    * Heart Rate: Digital display 0-300 bpm ±5%.
    * Heart Rate Alarm: On/Off displayed on monitor. User-selectable, tachycardia 60-280 bpm, bradycardia 20-100 bpm.
    * 1 Volt ECG Out: 1.0 volt/cm of deflection on strip chart recorder. < 25 ms delay from patient ECG input.
    * Display Format: Non-fade moving bar display.
    * SmartAlarms: Beeper/voice prompts indicate shockable rhythm.
    Display:
    * Screen Type: High-resolution display.
    * Screen Size: 5.6 inches (14.2 cm) diagonally.
    * Sweep Speed: 25 mm/sec.
    * Viewing Time: 4 seconds.
    * Channels: 2.
    * Information: Heart Rate, Lead/Pads, Alarm On/Off, NIBP, 12-Lead ECG, SpO2, EtCO2, AED Functions and Prompts, Defibrillator Test Function, Self Test Function, Error Corrections.
    Defibrillator:
    * Waveform: Damped sinusoid or ZOLL Rectilinear Biphasic.
    * Energy Selection: Selectable at 1, 2, 3, 4, 5, 6, 7, 8, 9, 10, 15, 20, 30, 50, 75, 100,150, 200, 300, 360 joules. (Delivered into 50Ω load.) Selected using controls on sternum paddle or device front panel. Rectilinear Biphasic energy selection up to 200 joules maximum.
    * Charge Time: Less than 7 seconds with a new fully charged battery (first 15 charges to max energy.) Depleted batteries will result in a longer defibrillator charge time.
    * Energy Display: Monitor display indicates both selected and delivered energy.
    * Synchronized Mode: Synchronizes defibrillator pulse to patient’s R-wave. “SYNC” message displayed on monitor. Marker on display and recorder paper identifies R-wave discharge point.
    * Advisory Function: Single analysis or programmable auto re-analyze x3 with programmable auto energy level selection, screen prompts, and voice prompts.
    * Charge Controls: Control on apex paddle and on device front panel.
    * Paddles: External anterior/anterior adult and pediatric. Adult paddles slide off to expose pediatric paddles.
    * Multi-Function Electrode (MFE) Pads: Specifically designed adult anterior/posterior pregelled ZOLL MFE Pads, and Multi-Function stat•padz packaged in pairs.
    * Built-In Defibrillator Tester: Tests defibrillator energy output and continuity of universal cable and paddles; documented on PCMCIA card and strip chart.
    * Defibrillation Advisory: Evaluates electrode connection and patient ECG to determine if defibrillation is required.
    * Shockable Rhythms: Ventricular fibrillation with amplitude > 100 µV and wide complex ventricular tachycardia with rates greater than 150 bpm.
    * Multi-Function Electrode Impedance Measurement Range: 0-250 ohms.
    Battery Packs:
    * Type: Rechargeable, sealed lead acid.
    * Recharge Time: 4 hours or less with integral charger.
    * Operating Time: For a new, fully charged battery pack at 20°C: 35 defibrillator discharges at maximum energy , or 3 hours of continuous ECG monitoring or 2.5 hours of continuous ECG monitoring/pacing at 60 mA, 80 beats/min.Additional parameters will effect operating time. Consult your operator’s guide.
    Specifications:
    * Size: 6.8 in (17.3 cm) high x 10.3 in (26.2 cm) wide x 8.2 in (20.8 cm) deep.
    * Weight: 11.5 lb. (5.23 kg) with Multi-Function Cable and battery; 13.5 lb. (6.14 kg) with paddles.
    * Design Standards: Meets or exceeds UL 2601, AAMI DF-39, AAMI DF-2, and IEC 601-2-4.
    * Patient Safety: All patient connections are electrically isolated.
    * Environmental: Operating Temperature: 0° to 55°C; Storage and Shipping Temperature: -40° to 65°C; Humidity: 5 to 95% relative humidity, non-condensing; Vibration: Mil Std 810E, Minimum Integrity Test; Shock: IEC 68-2-27, 50g 6mS half sine; Operating Pressure: 594 to 1060 mBar; Material Ingress: IEC 529, IP23; Electromagnetic Compatibility (EMC): CISPR; 11 Class B Radiated and Conducted Emissions; Electromagnetic Immunity: AAMI DF-2: IEC 801-3 to 20 V/m; Electrostatic Discharge: AAMI DF-2: IEC 1000-4-2; Conducted Susceptibility: IEC 1000-4-4, 1000-4-5, 1000-4-6.
    * AC Power: Meets all IEC, UL, and AAMI safety requirements.